posted on 2015-01-01, 00:00 authored by A Acikel, R M Singh, A Bouazza, Will GatesWill Gates, R K Rowe
An initially wet contact filter paper test (IW-CFPT) and an initially dry contact filter paper test (ID-CFPT) were used to examine the wetting paths of geosynthetic clay liners, including non-contact filter paper tests for comparative purposes. The CFPTs were applied to both geosynthetic clay liner faces to examine the effect of geotextile type on capillary contact. The non-woven geotextile face was found to be more likely to cause capillary breaks than the woven geotextile face. Both IW- and ID-CFPTs were found to be applicable to geosynthetic clay liners within their accurate upper matric suction measurement limits of 146 kPa and 66 kPa, respectively.

History

Journal

Geotechnique

Volume

65

Issue

9

Pagination

780 - 787

Publisher

ICE (Institution of Civil Engineers)

Location

London, Eng.

Language

eng

Publication classification

C Journal article; C1.1 Refereed article in a scholarly journal

Copyright notice

2015, ICE (Institution of Civil Engineers)