Deakin University
Browse

File(s) not publicly available

Volar scaphoid plating for nonunion: a multicenter case series study

journal contribution
posted on 2020-03-01, 00:00 authored by Kevin Eng, Stephen GillStephen Gill, Simon Hoy, Vivek Shridar, Natasha Van Zyl, Richard PageRichard Page
Background The volar scaphoid plate from Medartis (Medartis AG, Austrasse, Basel, Switzerland) is a variable angle titanium locking plate, preformed for the volar aspect of the scaphoid. It does not have compressive capability, and may act as a bridging device. It may provide an advantage over a compression screw where the pathoanatomy is less favorable to such a device with increased rotational stability. It may act as a buttress plate for correction of humpback deformity for example. It has been used in nonunions and with vascularized grafts. Questions Our study aims to assess the results of our patients with scaphoid nonunion treated with scaphoid volar plating over a larger number of patients. We aim to identify techniques to increase the success of plating. Methods Patients from our cohort were retrospectively reviewed. Operations were performed by three hand fellowship trained surgeons and in two centers. Inclusion involved a scaphoid plate procedure for a nonunion of the scaphoid with a minimum of 6 months of follow-up. Exclusions were those who had less than 6 months of follow-up. Data included demographics, patient-rated wrist evaluation (PRWE), a quick disabilities of the arm, shoulder, and hand (qDASH), visual analogue score, and range and grip. Radiology was reviewed. Results Thirty-two eligible patients were assessed. The mean age was 25 years (range 13–46), 2 were female and 15 were smokers. Mean follow-up postsurgery was 18 months. Twenty-nine of 32 patients united (90.6%) on computed tomography scan. Clinical assessment was performed in the 25 patients. The mean qDASH score was 12.5 (range 0–42) and mean PRWE was 11 (range 0–54). The mean arc of motion was 115 degrees. The mean grip strength was 39 kg compared with 41 kg on the nonoperated side. Conclusion We postulate that the plate acts like an internal bridging device, acting over a small distance, and inherent stability of the construct with structural graft and accurate reduction prior to plating is advantageous. Potential problems include plate impingement on the volar lip of the radius, particularly when trying to plate more proximal fractures. Ideally, it is utilized for mid to distal waist fractures.

History

Journal

Journal of wrist surgery

Volume

9

Issue

3

Pagination

225 - 229

Publisher

Thieme Publishers

Location

New York, N.Y.

ISSN

2163-3916

eISSN

2163-3924

Language

English

Publication classification

C1 Refereed article in a scholarly journal

Usage metrics

    Research Publications

    Categories

    No categories selected

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC